Free global shipping on orders over $50
12V Timer Relay for He Induction Switch - Automatic Closing Timeout, High Reliability Electrical Equipment for Industrial Automation & HVAC Systems
12V Timer Relay for He Induction Switch - Automatic Closing Timeout, High Reliability Electrical Equipment for Industrial Automation & HVAC Systems

12V Timer Relay for He Induction Switch - Automatic Closing Timeout, High Reliability Electrical Equipment for Industrial Automation & HVAC Systems

$4.36 $7.94 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:12 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:56877327

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

Feature:1. 4-time range is adjustable, the longest delay is 5 hours2. Turns on when there is a signal, and turns off when there is no signal3. High power load, maximum support for 10A current4. Adopted of high quality electronic components, and accuracy process, ensure for the durability5. Applicable to the combination of the stroke switch, the induction switch, the automatic closing of the timeout, the flowing monitoring of the pipeline product, etcSpecification:Item Type: Timer RelayVoltage: DC 5V/12V/24V (optional)Power Consumption: <1.0WOutput: Passive output (dry contact), relay set of normally open + normally closed output. Do not exceed 10A at most.Time Range: (4 files, selected by switch)First: Range 0.2 seconds-30 seconds, accuracy: 0.1 secondsSecond: Range 0.2 seconds - 300 seconds (5 minutes), accuracy: 0.3 secondsThird: Range 0.2 seconds-30 minutes, accuracy: 1.8 secondsFourth: Range 0.2 seconds-300 minutes (5 hours), accuracy: 18 secondsLife: More than 100,000 movementsInput: Voltage signal, valid signal above 1.5V, current requires at least 0.1mA.w-e-text table td,.w-e-text table th,;.w-e-text table,Package List:1 x Module

Product Features

High power load, maximum support for 10A current

4-time range is adjustable, the longest delay is 5 hours

Applicable to the combination of the stroke switch, the induction switch, the automatic closing of the timeout, the flowing monitoring of the pipeline product, etc

Turns on when there is a signal, and turns off when there is no signal

Adopted of high quality electronic components, and accuracy process, ensure for the durability

Customer Reviews

****** - Verified Buyer

We value your privacy

We use cookies and other technologies to personalize your experience, perform marketing, and collect analytics. Learn more in our Privacy Policy.

Top