Free global shipping on orders over $50
ICM Controls ICM253 Fan Delay Timer - Adjustable Off Delay 12-390 Seconds for HVAC, Bathroom Exhaust & Attic Fans | Perfect for Home & Commercial Ventilation Systems
ICM Controls ICM253 Fan Delay Timer - Adjustable Off Delay 12-390 Seconds for HVAC, Bathroom Exhaust & Attic Fans | Perfect for Home & Commercial Ventilation Systems

ICM Controls ICM253 Fan Delay Timer - Adjustable Off Delay 12-390 Seconds for HVAC, Bathroom Exhaust & Attic Fans | Perfect for Home & Commercial Ventilation Systems

$16.49 $29.99 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:18 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:45754787

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

Post-purge fan delay timer with adjustable 12-390-second time delay.

Product Features

UL 873 recognition for compressor applications

Post-purge fan delay timer

OFF delay purges ducts of residual air at the end of the heating/cooling cycle

Interrogation delay eliminates nuisance trips due to thermostat bounce/tampering

Customer Reviews

****** - Verified Buyer

Works as intended--the fan still runs ON SELECTED TIME after the condenser turned off from outside.I set mine to about 2 minutes after the thermostat cuts off the A/C.Installation:Like the diagram on the ICM253 unit.--1 and 4--bypass (undo and reconnect) the current GREEN wire from the Fan (1) and the GREEN wire from the thermostat (4)--2 and 3--tap (add into existing) into the 24vac from the RED (2) and BLUE/common/neutral (3) wiresI did not see the BLUE/COMMON/NEUTRAL 24vac wire once the furnace was opened.The wire diagram makes no sense at all !!!Google and YouTube did not help.So I removed the two screws and take out the cover that protected/covered the wirings and the 24v transformer (besides the breakers).I look for the 24v transformer and its Common/Neutral wire---It has wires out for the 24vac and wires in from the 240vac (labeled on the transformer...see picture).I saw the 24vac Common/Neutral wire (gray colored on this wire).I also saw that it was connected to the condenser outside...I simply tapped into that gray colored wire and done.Hope it helps someone out a bit.Have a great day.

We value your privacy

We use cookies and other technologies to personalize your experience, perform marketing, and collect analytics. Learn more in our Privacy Policy.

Top